Industry / ATEX and Hazardous Areas
Where flammable gases, vapours, dusts, or mists can occur, ATEX directives apply. Rixen's RW65_EX_II is intrinsically safe for Zones 0/1/2 and 20/21/22 — a mechanical differential pressure gauge with built-in 2-wire transmitter, from 40 Pa span.
A
EU Directive 2014/34/EU applies to equipment and protective systems in explosive atmospheres. Intrinsic safety (Ex ia) achieves this by limiting current and voltage in the circuit.
B
The measuring principle of the ring balance is entirely mechanical — no pressure-sensitive sensor, no diaphragm, no spring. The integrated transmitter reads only the rotation angle of the ring body contactlessly and converts it into a current signal. This transmitter is the intrinsically safe element.
C
Trusted by
In general hazardous area applications, Rixen instruments are trusted by: SIEMENS AG, Wacker Chemie, EnBW, Evonik AG, HONEYWELL, ABB.
Your project