Intrinsically safe differential pressure gauge for use in explosive atmospheres. Category II 1 GD, approved for Zones 0/1/2 and 20/21/22. The only Rixen device approved for direct use in the Ex zone.

Features
  • ATEX 2014/34/EU — II 1 GD Ex ia IIC/IIIC T4 Ga Da
  • Zones 0, 1, 2 (gas) and 20, 21, 22 (dust)
  • Ex ia — Zener barrier / isolating converter required on safe side
  • 4–20 mA passive
  • Mechanically readable scale without power
  • Up to 2 NAMUR contacts on request
  • Stainless steel housing (IP66) for offshore on request
Technical data
ATEX categoryII 1 GD Ex ia IIC/IIIC T4 Ga Da
Zones0, 1, 2 (gas) · 20, 21, 22 (dust)
ConformityATEX 2014/34/EU
Measuring principleMechanical ring balance with intrinsically safe 2-wire transmitter
Measuring rangesAll combinations between ±20 Pa and ±1,800 Pa
Most common ranges−50…+50 Pa · −25…+25 Pa · −10…+40 Pa · 0…50 Pa · −100…+100 Pa · 0…100 Pa · 0…500 Pa · 0…1.000 Pa
Output4–20 mA passive
Supply11–30 V DC (via Zener barrier / isolating amplifier)
Entity parametersUi ≤ 30 V DC · Ii ≤ 100 mA · Pi ≤ 620 mW · Ci, Li negligible
Max. measurement error±1.5 % FS or ±1.5 Pa
Scale150 × 150 mm, mechanically readable without power
Housing materialSteel RAL5015 / stainless steel (custom)
ProtectionIP65 (steel) · IP66 (stainless steel)
Connection8 mm nozzles
NAMUR contactsup to 2 optional (intrinsically safe, equivalent to IK contacts — no MK in Ex zone)
Factory calibration + DoCincluded in delivery
Configure instrument
Measuring range *
Overload protection
NAMUR contacts (optional)
Your configuration
RW65_EX_II
Range: -50…50 Pa

Intrinsic safety — what it means in practice

The RW65_EX_II is certified under the intrinsic safety protection concept (Ex ia) — the highest level, which tolerates two simultaneous faults without losing ignition safety. The device itself generates no ignitable energy internally.

At the boundary of an ATEX zone, a separation stage on the safe side is always mandatory, even when the end device is intrinsically safe. Three compatible options: Zener barrier (passive, low cost, requires IS earth), intrinsically safe isolating signal converter (active, galvanically isolated, easier to wire), intrinsically safe power supply (combines supply and isolation).

Based on our market research (as of July 2026), the RW65_EX_II is the only locally readable differential pressure gauge that combines an ATEX Category 1 approval (Zones 0/20, Ex ia) with a native measuring range from 40 Pa — decisive for cleanroom pressure cascades in the Ex zone, for example in pharma with solvent processes. Add drift-free mechanical measurement: every recalibration in the Ex zone means plant downtime and validation effort — the drift-free principle enables significantly extended intervals and reduces this effort considerably.

Frequently asked questions